Original CTX Go Salt 12 g/h electrode – Ref. 70327
Original CTX Go Salt 12 g/h electrode – Ref. 70327 subject to supplier availability.
Estimated delivery time: 3 to 7 business days
Description
Description
Original CTX Go Salt 12 g/h electrode
The CTX 70327 electrode is the original replacement for CTX Go Salt 12 g/h salt chlorinators.
It has 5 plates and restores the rated chlorine production capacity when the original cell has reached the end of its service life.
Allows you to replace only the electrode without changing the complete chlorinator, provided the other components are working correctly.
Replacement contents
Included: 1 original CTX electrode, reference 70327.
Not included: cell housing, locking nut, or complete chlorinator.
Technical specifications
| Reference | 70327 |
|---|---|
| Manufacturer | CTX / Fluidra |
| Product | Replacement electrode |
| Rated output | 12 g/h |
| Number of plates | 5 |
| Application | Salt electrolysis |
| EAN | 8435283954559 |
Compatible chlorinators
Equipment identified by Fluidra for electrode 70327.
| Equipment ref. | Chlorinator model |
|---|---|
| 70277 | CTX Go Salt 12 |
| 70278 | CTX Go Salt pH 12 |
Check the exact equipment reference before buying. Do not assume two electrodes are interchangeable just because they have the same output.
Comparison of CTX Go Salt electrodes
Identify the electrode that corresponds to the installed chlorinator model.
| Chlorinator model | Production capacity | Electrode ref. | Product |
|---|---|---|---|
| CTX Go Salt 7 | 7 g/h | 70326 | View electrode |
| CTX Go Salt 12 | 12 g/h | 70327 | Current model |
| CTX Go Salt 21 | 21 g/h | 70328 | View electrode |
| CTX Go Salt 30 | 30 g/h | 70329 | View electrode |
| CTX Go Salt 40 | 40 g/h | 70330 | View electrode |
Electrodes with different capacities are not necessarily interchangeable.
Frequently asked questions
How can I tell if the electrode is worn out?
Reduced chlorine production may indicate wear, but it can also be caused by salinity, pH, flow rate, scale buildup, or connection issues. It’s best to check these factors before replacing the cell.
Does the electrode need to be replaced if it has limescale buildup?
Not necessarily. Scale buildup can reduce performance without the electrode being worn out. Before replacing it, check its condition and follow the cleaning procedure recommended by the manufacturer. Avoid scraping the plates or using unauthorized products.
What precautions should I take when replacing it?
Disconnect the power supply and stop filtration. Isolate and depressurize the circuit before removing the cell. Check the condition of the seals, housing, and connections, and follow the manufacturer’s instructions. Check for leaks before restarting the system.
What factors affect the electrode’s service life?
Service life depends on operating hours, water quality, salinity, scale buildup, and maintenance. Keeping water parameters within the manufacturer’s recommended ranges helps reduce premature wear.




