AquaChek
AquaChek Yellow 4-in-1 test strips – 50 strips | 19121
SKU:19121
Delivery: 3 to 7 business days
8,95 €Unit price /Sold outStarpool
OTO reagent for chlorine analyzers
SKU:90910
Delivery: 3 to 7 business days
1,33 €Unit price /Sold outCTX
Phenol red liquid reagent for measuring pool pH, 250 ml – 03309
SKU:03309
Delivery: 3 to 7 business days
23,06 €Unit price /Sold outAquaChek
Aquachek white salt test strips for salt levels.
SKU:19122
Delivery: 3 to 7 business days
13,24 €Unit price /Sold outCTX
CTX OTO reagent for total chlorine, 250 ml bottle – 03308
SKU:03308
Delivery: 3 to 7 business days
24,28 €Unit price /Sold outLovibond
DPD 1 reagent tablets for photometers, 250 pcs. Lovibond
SKU:03009
Delivery: 3 to 7 business days
14,88 €Unit price /Sold outLovibond
Lovibond Phenol Red photometer reagent box. 250 units.
SKU:03019
Delivery: 3 to 7 business days
14,88 €Unit price /Sold outAstralPool
DPD-1 reagent for photometers, box of 250 tablets. Astralpool.
SKU:41919
Delivery: 3 to 7 business days
17,00 €Unit price /Sold outAquaChek
Pack of 2 AquaChek Yellow 4-in-1 – 100 test strips
SKU:19121X2
Delivery: 3 to 7 business days
22,32 €Unit price /Sold outFTK
Fast Total Hardness Test Kit. FTK-118. 102847.
SKU:102847
Delivery: 3 to 7 business days
10,42 €Unit price /Sold outStarpool
Phenol Red reagent for pH analyzers.
SKU:90911
Delivery: 3 to 7 business days
1,88 €Unit price /Sold outStarpool
5-in-1 test strip kit. Starpool.
SKU:90906
Delivery: 3 to 7 business days
5,40 €Unit price /Sold outTaylor
Taylor K-2006 multiparameter analyzer test kit
SKU:102796
Delivery: 3 to 7 business days
188,42 €Unit price /Sold outStarpool
Starpool pool pH and chlorine test kit – 90929
SKU:90929
Delivery: 3 to 7 business days
6,13 €Unit price /Sold outAquaChek
Aquachek red test strips for bromine, hardness, alkalinity, and pH.
SKU:19125
Delivery: 3 to 7 business days
13,49 €Unit price /Sold outAquaChek
Test strips for AquaChek TruTest
SKU:19120
Delivery: 3 to 7 business days
18,35 €Unit price /Sold outAstralPool
PHENOL reagent for photometers
SKU:41918
Delivery: 3 to 7 business days
12,70 €Unit price /Sold outHanna Instrument
HANNA liquid reagent for free chlorine.
SKU:HI93701-F
Delivery: 3 to 7 business days
37,68 €Unit price /Sold outLovibond
Lovibond Pooltester chlorine and pH analyzer kit.
SKU:151600
Available to order
16,86 €Unit price /Sold out
Preguntas frecuentes sobre Water analysis
My water is cloudy despite adding disinfectant, and I need to know what to test first. Which equipment should I choose?
The first step is to determine the exact pH value and the concentration of free chlorine available in the pool. A pH above 7.6 drastically reduces chlorine effectiveness and promotes mineral salt precipitation that clouds the water.
For accurate diagnoses of recurring imbalances, a digital meter with an absorbance reading eliminates the visual uncertainty of traditional strips. With the Scuba II Pool Photometer, you can measure free chlorine, total chlorine, pH, isocyanuric acid and alkalinity in just minutes using standardized reagent tablets.
What is the difference between a manual colorimetric kit and a photometer for water analysis?
The main difference lies in the reading method and the accuracy of the results obtained. While manual kits rely on subjective visual comparison against a color scale, photometers use optical sensors to quantify light absorption at specific wavelengths.
- Manual kits: They use liquid reagents such as phenol red or quick-test reagents, providing an approximate estimate that is subject to ambient light variations.
- Digital photometers: They use standardized cuvettes and DPD reagent tablets to provide precise digital readings to the hundredths place.
- Analytical range: Electronic models can diagnose the concentration of solar stabilizer to prevent treatment from being blocked.
I’m going to monitor a heavily used community pool. What should I check before buying a professional analyzer?
You should check the equipment's measurement repeatability and its ability to break down chlorine into its different chemical fractions. In shared facilities, accurately measuring combined chlorine is essential, as it is a direct cause of irritation and pungent odors.
To reliably meet these technical requirements with instrument-grade accuracy, it is advisable to choose professional-grade equipment such as the Lovibond MD200 3-in-1 Chlorine, pH and Cyanuric Acid Photometer. This instrument ensures rigorous monitoring of pH, free chlorine and cyanuric acid using sealed optical systems with moisture protection, and can withstand continuous use at the poolside.
What exact parameters must be measured in water analysis to prevent green water?
The essential parameters for ensuring safe water are a pH strictly between 7.2 and 7.6, and free chlorine between 0.5 and 2.0 ppm for conventional treatments. Maintaining these concentrations immediately prevents green water and organic deposits from forming on the lining.
Total alkalinity must also be checked to ensure it is between 80 and 120 ppm, where it acts as a pH buffer and prevents uncontrolled fluctuations. In pools treated with stabilized chlorine, measuring cyanuric acid makes it possible to confirm that levels do not exceed 50 ppm, above which the disinfectant loses its shock treatment capacity.
Is it worth switching from test strips to a digital photometer if I have a saltwater chlorination system?
Yes, investing in photometric technology is well worth it because salt electrolysis systems produce constant pH fluctuations that require precise adjustments. An inaccurate reading can lead to excessive additions of reducer or increase scale buildup on the cell electrodes.
The electronic meter accurately measures the active free chlorine generated by salt electrolysis without being affected by dissolved salts. This optimizes chlorinator output, extends the equipment's service life, and reduces overall chemical regulator consumption throughout the season.
How does the DPD reagent affect water test results?
DPD-formulated tablets accurately determine the different stages of the disinfectant by reacting specifically with each chemical species. They consist of two complementary reagents essential for any technical inspection:
- DPD 1 tablets: These react instantly with the available free chlorine, showing its actual germicidal capacity at that moment.
- DPD 3 tablets: These are added to the same sample as DPD 1 to measure total chlorine. The mathematical difference between the two measurements reveals the exact level of chloramines.
Using sealed tablets prevents the premature degradation that liquid solutions undergo in ambient heat.
I've been advised to test the water once a week, but I notice a chlorine smell. What should I check?
A strong smell of an indoor pool does not indicate excess chlorine, but rather a high concentration of combined chlorine formed when chlorine binds with organic matter. To eliminate this problem, free chlorine and total chlorine must be measured separately using verified reagents.
When combined chlorine exceeds 0.6 ppm, an oxidizing treatment or shock chlorination is necessary to destroy the irritating compounds. Increasing sampling frequency to twice a week during periods of heavy use makes it possible to rebalance the system before swimmers experience eye irritation or fungal skin infections.