Zodiac Dual Link WW000177 – Automatic pH and Redox regulation
Zodiac Dual Link WW000177 – Automatic pH and Redox regulation subject to supplier availability.
Estimated delivery time: 3 to 7 business days
Description
Description
The Zodiac Dual Link WW000177 enables automation of both pH control and measurement of the pool water’s Redox potential (ORP), providing more comprehensive control of the water balance and disinfection.
The system combines a pH probe and a Redox probe installed on the POD Kit, integrating directly with the control unit of the compatible Zodiac chlorinator.
Automatic pH and Redox control
Zodiac Dual Link combines automatic pH measurement with Redox potential control, enabling management of the water balance and disinfection level from the compatible Zodiac chlorinator.
- Automatic pH measurement.
- Redox potential (ORP) measurement.
- Automatic acid corrector dosing.
- Two-point pH calibration: pH 4 and pH 7.
- Redox calibration using a 470 mV buffer solution.
- Factory pH setpoint of 7.2.
- Factory Redox setpoint of 700 mV.
- Measurement via POD Kit.
Technical specifications
| Reference | WW000177 |
|---|---|
| Model | Zodiac Dual Link |
| Regulation | pH + Redox |
| pH range | 0.0–12.0 pH |
| pH accuracy | 0.1 pH |
| Redox range | 100–1000 mV |
| Redox accuracy | 10 mV |
| Factory pH setpoint | 7,2 |
| Redox setpoint | 700 mV |
| Peristaltic pump flow rate | 1.8 L/h |
| Maximum back pressure | 1.5 bar |
| Probe tolerance | 0–60 °C |
| Maximum water speed | ≤ 2 m/s |
| Dosing | Acid |
What does Zodiac Dual Link include?
- pH probe.
- Redox probe.
- pH 4 buffer solutions.
- pH 7 buffer solutions.
- 470 mV Redox buffer solutions.
- Hole saw.
- Pipe kit.
- POD Kit.
3 units of each pH 4 and pH 7 buffer solution are supplied for and 3 units of 470 mV Redox buffer solution for probe calibration.
Installation
The Dual Link module connects directly to the control unit of the compatible chlorinator. Zodiac specifies a distance of 1,5 m between the module and the probes/cell.
El Kit POD debe instalarse después de la filtración and heating and before the cell. The probes must remain in a vertical position to ensure a correct measurement.
Frequently asked questions about Zodiac Dual Link
What is the difference between Zodiac pH Link and Dual Link?
pH Link is designed for automatic pH control, whereas Dual Link also adds Redox potential measurement to control the disinfection level together with the compatible chlorinator.
Which chlorinators is Dual Link compatible with?
Zodiac indicates compatibility with eXO® iQ eXO® iQ LS and Hydroxinator® iQ.
Does it include the pH and Redox probes?
Yes. Dual Link includes the pH probe and the Redox probe, as well as of the buffer solutions required for calibration.
What values are factory-configured?
Zodiac sets a pH setpoint of 7.2 at the factory and a a Redox setpoint of 700 mV.
Where should the POD Kit be installed?
It must be installed after filtration and heating and before the chlorinator cell, keeping the probes in a vertical position.