Money-Back Guarantee + info

Secure Payment and Financing + info

AstralPool Niagara pump prefilter lid O-ring – 4404090101

AstralPool  |  SKU: 4404090101
6,60 €
Taxes included

Original AstralPool lid O-ring 4404090101 for Corona 400, 500, and 600 filters.

Estimated delivery time: 3 to 7 business days

Secure payment in installments + info

Free Shipping from €150 in mainland Spain, except for some heavy or bulky products + info

Personalized Advice Contact

Money-Back Guarantee + info

Description

Before buying: original AstralPool 4404090101 O-ring for the prefilter lid of AstralPool Niagara pumps (NI050 to NI300 series). Not suitable for Corona filters: the O-ring for Corona filters Ø400, Ø500 and Ø600 is the set of 2 gaskets 4404090103. Check your pump model before buying.

Quick summary

The AstralPool 4404090101 lid O-ring seals the closure between the transparent lid and the body of the Niagara pump prefilter. When it hardens, deforms or cracks, the pump draws in air through the lid, loses flow or drips when stopped.

LidPump prefilter
1O-ring
OriginalAstralPool

Spare part identified by Fluidra in the exploded views of single-phase and three-phase Niagara pumps, including 60 Hz versions.

Buy with confidence

  • Brand: AstralPool / Fluidra
  • Reference: 4404090101
  • EAN-13: 8435283929199
  • Type: O-ring
  • Position: prefilter lid
  • Application: Niagara pumps
  • Contents: 1 gasket
  • Spare part: original AstralPool

Technical specifications

Feature Value Feature Value
Reference 4404090101 Manufacturer AstralPool / Fluidra
Fluidra designation Lid O-ring Type O-ring
Application Niagara pump prefilter lid Sales unit 1 unit
EAN-13 8435283929199 Compatibility According to Fluidra exploded view

AstralPool / Fluidra Compatibility

Reference 4404090101 appears in the exploded views of the following Niagara pumps. Expand each block to view the versions.

Niagara 0.5 HP

NI050M, NI050T

Niagara 0.75 HP

NI075M, NI075M-O, NI075M60, NI075T, NI075T60

Niagara 1 HP

NI100M, NI100M-O, NI100M60, NI100T, NI100T-M, NI100T60

Niagara 1.5 HP

NI150M, NI150M-O, NI150M60, NI150T, NI150T-M, NI150T60

Niagara 2 HP

NI200M, NI200M-O, NI200M60, NI200T, NI200T-M, NI200T60

Niagara 3 HP

NI300M, NI300M-O, NI300M60, NI300T, NI300T-M, NI300T-M-O and other versions

Important: this gasket is not suitable for AstralPool Corona filters (04584, 04585 and 04586). For those filters, Fluidra specifies the set of 2 O-rings 4404090103. Do not use it in other pumps either without checking that their parts list includes reference 4404090101.

Installation and maintenance

Stop the pump and disconnect the power supply. Close the suction and discharge valves before opening the prefilter lid. Remove the old gasket, clean the housing and the lid, and fit the new gasket without twisting it.

Apply a thin layer of silicone lubricant; never use petroleum jelly or petroleum-based greases, as they damage the rubber. Close the lid by hand, without tools, and check that no air enters when starting the pump.

Frequently asked questions

What is gasket 4404090101 for?

It seals the prefilter lid closure on AstralPool Niagara pumps.

Is it suitable for the Corona filter?

No. Corona Ø400, Ø500, and Ø600 filters use the set of 2 O-rings 4404090103.

How do I know if I need to replace it?

If the pump draws air through the lid, the prefilter does not fill with water, it drips when stopped, or the gasket is hard, flattened, or cracked.

Is it suitable for all Niagara pumps?

Fluidra specifies it for Niagara pumps from 0.5 to 3 HP, single-phase, three-phase, and 60 Hz. Check the model on your pump's nameplate.

What lubricant should I use?

Silicone lubricant. Avoid petroleum jelly and petroleum-based greases.

Is it an original spare part?

Yes, it is the original AstralPool spare part with reference 4404090101.

I have doubts about compatibility, what should I do?

Write to us with your pump model or a photo of its nameplate, and we will confirm whether it is the correct part.