Idegis Domotic DOM-18P/24 electrode 24 g/h – Ref. R-059
Idegis Domotic DOM-18P/24 electrode 24 g/h – Ref. R-059 subject to supplier availability.
Estimated delivery time: 3 to 7 business days
Description
Description
Original Idegis Domotic R-059 electrode
The Idegis R-059 electrode is an original replacement part for salt chlorinators in the Domotic and Domotic 2 families, with a nominal output of 24 g/h of chlorine.
It features 7 self-cleaning coated titanium plates, designed to generate chlorine through salt electrolysis and limit scale buildup during operation.
Allows you to replace the worn electrode assembly without replacing the entire chlorinator, provided the equipment's other components are in good condition.
Replacement part contents
Includes: 1 original Idegis R-059 electrode assembly with 7 plates.
Does not include: cell housing, EPDM gasket, or separate mounting kit.
The R-300 gasket and R-TORN 08 anchoring kit are listed as separate references in the Idegis catalog.
Technical specifications
| Reference | R-059 |
|---|---|
| Manufacturer | Idegis |
| Product type | Electrode assembly |
| Nominal output | 24 g/h |
| Number of plates | 7 |
| Material | Coated titanium |
| Cleaning system | Self-cleaning |
| Compatible ranges | Domotic / Domotic 2 |
| Application | Salt electrolysis |
| Previous name | DOM-18P/24 |
Chlorinators compatible with R-059
Replacement part identified for the following 24 g/h models:
| Chlorinator model | Series |
|---|---|
| DOM-24 | Domotic |
| DOM-24PH | Domotic pH |
| DOM-24+ | Domotic |
| DOM2-24 | Domotic 2 |
| DOM2-24PH | Domotic pH |
| DOM2-24+ | Domotic 2 |
Also identified in earlier documentation as DOM-18P/24. Always check the equipment nameplate and the replacement part reference.
Important: This electrode is reference R-059 for conventional-salinity Domotic units. Do not confuse it with the R-059 LS, used in low-salinity Domotic versions. For Domotic 2 units, the STEM-NTC temperature sensor is supplied separately and is not included with the electrode assembly.
Idegis Domotic electrode comparison
Each reference corresponds to a chlorinator capacity and model.
| Chlorinator model | Production capacity | Electrode ref. | Product |
|---|---|---|---|
| DOM-10P/12 | 12 g/h | R-058 | View electrode |
| DOM-18P/24 | 24 g/h | R-059 | Current model |
| DOM-25P/32 | 32 g/h | R-060 | View |
| DOM-40P/42 | 42 g/h | R-304 | View |
References by official Idegis Domotic / Domotic 2 range. Do not interchange electrodes with different capacities without technical confirmation.
Frequently asked questions
How can I tell if the R-059 electrode is worn out?
Lower chlorine production may indicate electrode wear, but it can also be caused by incorrect salinity, insufficient flow, scale buildup, or electrical problems. Check these causes before replacing the cell.
Should I replace it if it has limescale?
Not necessarily. Limescale can reduce performance even if the plates are not worn out. Check the water conditions and follow only the manufacturer's cleaning instructions. Do not scrape or strike the plates.
What precautions should I take when replacing the electrode?
Disconnect the power supply and stop filtration. Isolate and depressurize the circuit before removing the cell. Check the seals, connections, and fasteners, following the equipment's official procedure.
What affects the service life of the R-059?
Operating hours, salinity, temperature, water chemistry balance, scale buildup, and maintenance affect wear. Keeping the parameters recommended by Idegis helps prevent premature failures.



