SACI TOP WINNER 200 T pool pump, 2 HP three-phase
SACI TOP WINNER 200 T pool pump, 2 HP three-phase subject to supplier availability.
Estimated delivery time: 3 to 7 business days
Description
Description
The SACI TOP WINNER 200 T self-priming pump is designed for filtration in private pools. It features a large-capacity prefilter, an IE3 three-phase motor and DN 50/63 connections. Its optimized hydraulics reduce noise and consumption compared with the standard WINNER design, according to SACI.
Technical specifications
| Feature | Value |
|---|---|
| Manufacturer | SACI |
| Series | TOP WINNER |
| Model | 200 T |
| SACI reference | 36104111 |
| Power | 2 HP / 1.5 kW |
| Power supply | 230/400 V three-phase |
| Rated current at 230 V | 6 A |
| Rated current at 400 V | 3.5 A |
| Motor | IE3 asynchronous motor, 2,900 rpm |
| Protection / insulation | IP55 / Class F |
| Housing material | Glass fiber-reinforced polypropylene |
| Shaft | AISI 316 stainless steel |
| Impeller | Noryl |
| Connections | DN 50/63 (thread and fittings) |
Hydraulic performance
Head according to operating flow rate:
| Flow rate (m³/h) | Head (m.w.c.) |
|---|---|
| 6 | 28,2 |
| 8 | 26,5 |
| 10 | 24,3 |
| 12 | 22 |
| 14 | 19 |
| 16 | 15,2 |
| 18 | 10,5 |
| 20 | 3 |
SACI catalog performance. The highlighted point (10 m³/h and 24.3 m.w.c.) does not represent constant pressure.
Dimensions and installation
| Dimension | TOP WINNER 200 T measurement |
|---|---|
| A | 216 mm |
| B | 278 mm |
| B* | 320 mm |
| C | 279 mm |
| C* | 321 mm |
| E | 310 mm |
| H | 208 mm |
| I | 164 mm |
| L | 583 mm |
| L* | 625 mm |
Drawing common to the TOP WINNER family. Dimensions marked with an asterisk include the connecting fittings.
Recommended applications
- Filtration and recirculation in private pools.
- Replacement for a standard WINNER pump, after checking the flow rate, connections, and available space.
The “Ring Lock” cover opens with a quarter turn; the pump features a large pre-filter.
SACI TOP WINNER pump comparison
Compare the 14 models in the series by power, power supply, and head at the same flow rate. Single-phase references end in M and three-phase references in T.
| SACI reference | Model | Power | Power supply | Head at 10 m³/h |
|---|---|---|---|---|
| 36104100 | 33 M | 0.33 hp | Single-phase | 9 m.w.c. |
| 36104101 | 33 T | 0.33 hp | Three-phase | 9 m.w.c. |
| 36104102 | 50 M | 0.5 hp | Single-phase | 11.5 m.w.c. |
| 36104103 | 50 T | 0.5 hp | Three-phase | 11.5 m.w.c. |
| 36104104 | 75 M | 0.75 hp | Single-phase | 14 m.w.c. |
| 36104105 | 75 T | 0.75 hp | Three-phase | 14 m.w.c. |
| 36104106 | 100 M | 1 hp | Single-phase | 18 m.w.c. |
| 36104107 | 100 T | 1 hp | Three-phase | 18 m.w.c. |
| 36104108 | 150 M | 1.5 hp | Single-phase | 21.5 m.w.c. |
| 36104109 | 150 T | 1.5 hp | Three-phase | 21.5 m.w.c. |
| 36104110 | 200 M | 2 hp | Single-phase | 24.3 m.w.c. |
| 36104111 | 200 T · Current model | 2 hp | Three-phase | 24.3 m.w.c. |
| 36104112 | 300 M | 3 hp | Single-phase | 29 m.w.c. |
| 36104113 | 300 T | 3 hp | Three-phase | 29 m.w.c. |
Scroll horizontally to view the full table. Heads at 10 m³/h according to the SACI datasheet; final selection should be based on the hydraulic curve. Available models can be viewed through their links; the rest will be added once their datasheets are ready.
Frequently asked questions
What is the difference between the TOP WINNER 200 M and the 200 T?
Both have the same power and hydraulic curve. The 200 M uses a 230 V single-phase power supply, while the 200 T requires a 230/400 V three-phase power supply.
Can it replace a conventional WINNER pump?
SACI states that the design is interchangeable with the standard WINNER. Before replacing it, check the connections, dimensions, and performance requirements for your installation.
Is it a variable-speed pump?
No. The TOP WINNER 200 T has a fixed speed. Variable-speed solutions are sold in specific configurations.
How do I choose the right power?
Calculate the required filtration flow rate and the circuit’s total dynamic head; then select the model that delivers that flow rate at the operating point.