FTK
Fast Total Hardness Test Kit. FTK-118. 102847.
SKU:102847
Delivery: 3 to 7 business days
10,42 €Unit price /Sold outFTK
Total hardness reagent TH-12, 22 ml.
SKU:102845
Available to order
13,09 €Unit price /Sold outFTK
Fast Test Kit Free Chlorine, Total Chlorine and pH. FTK-101. 102077.
SKU:102077
16,76 €Unit price /Sold outFTK
FTK-125 test kit for free chlorine, total chlorine, bromine, pH, and alkalinity – 102846
SKU:102846
Available to order
27,77 €Unit price /Sold outFTK
Total hardness reagent TH-11, 22 ml.
SKU:102844
Available to order
13,09 €Unit price /Sold out
Preguntas frecuentes sobre FTK
I have a saltwater pool, and the water often gets cloudy. Which FTK kit should I use to diagnose the problem?
An FTK test kit that measures free chlorine, pH, and cyanuric acid is essential for diagnosing imbalances in saltwater chlorinators.
In pools with electrolysis, cloudiness is usually caused by an uncalibrated pH above 7.6 or stabilizer saturation. For an accurate digital reading without visual estimation errors, the Scuba II Pool Photometer measures free and total chlorine from 0.1 to 6.0 ppm and pH from 6.5 to 8.4.
Make sure the alkalinity reading stays between 80 and 120 ppm before adjusting disinfectant levels.
What is the difference between a visual FTK test and a digital photometer?
The main difference lies in the reading system: a visual test relies on subjective comparison with a color scale, while a photometer measures light transmittance using an electronic sensor.
The equipment has specific operational characteristics:
- FTK visual kits: use liquid reagents or fast-dissolving tablets for indicative chlorine and pH readings in 0.5 ppm increments.
- Portable photometers: use slow-dissolving tablets and offer a resolution of 0.01 ppm, minimizing human error.
- Resistance to ambient light: the photometer zeroes itself using the water sample to eliminate light interference.
For commercial facilities or discerning users in 2026, photometry eliminates critical deviations in chemical dosing.
I'm opening my pool for the 2026 season, and I don't know if the reagents in my FTK kit expire from one year to the next. Should I replace them?
Reagents for FTK test kits lose analytical effectiveness if they are past their expiration date or have been exposed to moisture and heat over the winter.
DPD tablets sealed in aluminum blister packs retain their reactive properties for up to three years under optimal conditions, but liquid dropper reagents lose accuracy twelve months after opening. Using degraded tablets gives false negative readings for free chlorine, leading to harmful overchlorination. If you notice persistent discrepancies after checking your kit, balance the water with Quimiclor PS 5 Efectos Quimicamp 5 kg – 250 g Tablets (Multi-Action Chlorine), keeping the readings within health regulations.
Which parameters does a professional FTK analyzer measure?
A professional FTK tester quantitatively analyzes five key parameters for pool water safety: free chlorine, combined chlorine, pH, total alkalinity, and cyanuric acid.
Each parameter serves a specific monitoring purpose:
- Free residual chlorine: quantifies the active disinfectant between 0.5 and 2.0 ppm using DPD 1 reagent.
- Combined chlorine: calculates the presence of irritating chloramines by subtracting free chlorine from total chlorine (DPD 3).
- Equilibrium pH: determines disinfection effectiveness and prevents corrosion at values of 7.2 to 7.6, using phenol red.
- Cyanuric acid: measures the chlorine's sunscreen; levels must not exceed 50 ppm to prevent chemical lockout.
Maintaining this control avoids wasting unnecessary chemicals.
I'm measuring chlorine with my kit, but the sample immediately loses its color when I add the tablet. Why does this happen?
The water sample immediately bleaches the DPD reagent when the chlorine concentration exceeds 10 ppm.
This destructive oxidation phenomenon typically occurs after shock treatments or dosing errors. To resolve this issue and obtain a valid reading, dilute the pool sample by 50% with distilled water, take the measurement as usual, and multiply the result by two. If you manage community facilities that require consistent accuracy despite these fluctuations, the Lovibond MD200 3-in-1 Photometer for Chlorine, pH, and Cyanuric Acid prevents range errors with its narrow-wavelength interference filters.
How do I calibrate an FTK pool test?
FTK visual scale meters do not require electronic calibration, but the measuring cells must be thoroughly cleaned with demineralized water after each use.
For digital or field photometric devices, calibration is performed by setting the zero point before each analysis cycle. Fill the cell with 10 ml of the water to be tested without adding reagents, insert it into the reading chamber, and press the zeroing command. This step compensates for the water's natural turbidity and any scratches on the glass. Replace plastic test tubes if they become cloudy or develop yellowish stains to maintain reproducible readings.
I want to buy a reliable FTK test kit, but I'm worried about making mistakes when taking samples. What steps ensure accurate measurements?
To ensure an accurate chemical measurement, always take the water sample at least 30 centimeters below the surface and away from the skimmers or return jets.
Follow these operating guidelines during the process:
- Rinse the cell twice with water from the pool before filling it to the 10 ml mark.
- Never touch reagent tablets with bare fingers, as skin oils affect the pH and DPD readings.
- Dissolve the tablet using the plastic stirring rod without stirring vigorously to prevent bubbles from forming in the optical beam.
- Perform the color comparison or photometric reading within 60 seconds of complete dissolution.
By following this strict protocol, your FTK kit will provide reproducible data for safely treating your pool.