AstralPool Leader RX peristaltic pump 3 l/h for Redox control 77059
AstralPool Leader RX peristaltic pump 3 l/h for Redox control 77059 subject to supplier availability.
Estimated delivery time: 3 to 7 business days
Description
Description
Main controls and functions
Automatic Redox regulation
The Leader RX uses the Redox electrode reading to control proportionally until the chlorine dosing reaches the setpoint programmed setpoint.
- Adjustable setpoint between 300 and 800 mV.
- Proportional control through ON/OFF cycles.
- 150-second operating cycle.
- One-point calibration at 468 mV.
- Probe status detection.
Display and safety
The unit allows direct display of the measured Redox value and control dosing using the programmed setpoint.
- Instantaneous Rx value display.
- Programmable setpoint.
- Temporary overdosing alarm.
- Possible product depletion warning.
- Probe status monitoring.
What reference 77059 includes
- Leader RX digital peristaltic pump.
- 1 1/2" injection valve.
- 1 1/2" suction filter.
- 2 m of 4 × 6 mm PE discharge tubing.
- 2 m of 4 × 6 mm PVC suction tubing.
- 1 RX electrode with epoxy body.
- 1 468 mV buffer solution.
- 2 Ø50 grip collars with 1/2" connection.
- 1 1/2" PP tube probe holder.
Installation diagram
Technical specifications
Swipe horizontally to view all data.| Brand | AstralPool / Fluidra |
|---|---|
| Reference | 77059 |
| Model | Leader RX |
| Pump type | Digital peristaltic |
| Application | Chlorine dosing |
| Control | Redox / Rx |
| Setpoint range | 300–800 mV |
| Calibration | 468 mV |
| Flow rate | 3 l/h (50 cc/min) |
| Maximum pressure | 1 bar / 14.5 PSI |
| Speed | 20 rpm |
| Tube material | Santoprene |
| Tube size | 5,8 × 9,4 mm |
| Power supply | 230 Vac / 50 Hz |
| Power consumption | 13 W |
| Probe connection | BNC |
| Protection rating | IP65 |
| Weight | 1.6 kg |
Frequently asked questions
How does the Leader RX 77059 regulate chlorine dosing?
It uses the Redox electrode measurement as a reference and controls proportionally through ON/OFF cycles until reach the programmed setpoint between 300 and 800 mV.
Does it include the Redox electrode?
Yes. Reference 77059 includes an RX electrode with an epoxy body and 468 mV buffer solution for calibration.