AstralPool
Complete lid ring for AstralPool Vesubio and Volcano pool filter – 4404260205
SKU:4404260205
Delivery: 3 to 7 business days
77,35 €Unit price /Sold outHayward
Hayward Super Pump pump prefilter basket – SPX1600M
SKU:SPX1600M
Delivery: 3 to 7 business days
21,07 €Unit price /Sold outAstralPool
SKU:06434
Delivery: 3 to 7 business days
18,65 €Unit price /Sold outHayward
Hayward Selector Valve Connector and Coupling Kit
SKU:SPX0719KIT
Delivery: 3 to 7 business days
64,46 €Unit price /Sold outAstralPool
1" - 175 mm. collector arm AstralPool. 2-piece kit.
SKU:4404300915
Delivery: 3 to 7 business days
8,42 €Unit price /Sold outAstralPool
1" - 110 mm. collector arm AstralPool. 2-piece kit.
SKU:4404300917
Delivery: 3 to 7 business days
8,83 €Unit price /Sold outEspa
New Silen pump prefilter lid nut. Espa.
SKU:133348
Delivery: 3 to 7 business days
13,80 €Unit price /Sold outHayward
5-way 1½" multiport valve seat gasket. HAYWARD
SKU:SPX0710XD
Available to order
26,77 €Unit price /Sold outAstralPool
Selector valve connection gaskets 1 ½". Astralpool.
SKU:4404120205
Delivery: 3 to 7 business days
6,18 €Unit price /Sold outProductos QP
Black lid gasket for QP Coral pool filter with screw closure 01012005
SKU:01012005
Delivery: 3 to 7 business days
19,34 €Unit price /Sold outSaci
SACI Winner and Koda prefilter lid closure wrench 92400013
SKU:92400013
Available to order
11,40 €Unit price /Sold outAstralPool
AstralPool Victoria, Sena and compatible pump mechanical seal - 4405010118
SKU:4405010118
Delivery: 3 to 7 business days
25,60 €Unit price /Sold outProductos QP
6-way side-mounted selector valve 2" without unions for QP / Coral filters – 500482N
SKU:500482N
Delivery: 3 to 7 business days
64,46 €Unit price /Sold outAstralPool
AstralPool Ramses 4404250111 selector valve for pool filters
SKU:4404250111
Delivery: 3 to 7 business days
117,02 €Unit price /Sold outAstralPool
Black D.220 lid for Astralpool filters.
SKU:4404160847
Delivery: 3 to 7 business days
31,87 €Unit price /Sold outProductos QP
SKU:512556T80
Delivery: 3 to 7 business days
39,00 €Unit price /Sold outHidrowater
Pressure gauge with gasket for HidroWater S500 / S650 Bluetank filter
SKU:RPE-020131
Delivery: 3 to 7 business days
22,21 €Unit price /Sold outProductos QP
Transparent lid for QP Ciclón and Rubí and Coral Neptuno and Océano filters – 01012071
SKU:01012071
Delivery: 3 to 7 business days
38,18 €Unit price /Sold outSaci
Saci Pumps Winner pump drain plug
SKU:92400034
Delivery: 3 to 7 business days
3,96 €Unit price /Sold outHayward
SKU:SP0710X32E
Delivery: 3 to 7 business days
160,00 €Unit price /Sold out
Preguntas frecuentes sobre Filtration spare parts
I’ve noticed sand entering the pool through the return jets, and my filtration system is losing pressure. Which replacement part do I need?
Silica sand coming out through the return jets indicates that one or more laterals at the bottom of the tank are broken. When these filter slots crack due to material fatigue or excess pressure, sand grains pass through the physical barrier and return to the pool. To fix this problem, empty the filter media, inspect the central manifold, and replace the damaged slotted arms with parts that have the same thread pitch.
Also check that the base gasket and upper diffuser have no play. If the entire tank is deformed due to excessive operating pressure, it is best to replace the unit with a dedicated tank, such as the Starpool Ø400 mm pool sand filter without pump, with multiport valve, to ensure the circuit is watertight.
How to choose filtration replacement parts based on connection diameter
The key criterion for selecting filtration replacement parts is checking the external and internal thread measurements of the system pipes. Installing the wrong size can restrict flow or cause immediate leaks due to misalignment.
- 1 ½-inch connections: standard for pipes with a 50 mm outside diameter, commonly used with pumps up to 0.75 hp and flow rates below 10 m³/h.
- 2-inch connections: required for 63 mm pipes, designed to handle high flow rates and reduce pressure loss in high-power circuits.
- Metric or imperial thread: check whether the fitting requires a flat gasket or Teflon tape to ensure a completely watertight seal under pressure.
Always check the technical specifications for the original multiport valve before finalizing your purchase of a replacement part.
Water leaks from the drain pipe when the filtration system is running. Do I need to replace the entire valve or just one part?
A continuous leak to the drain outlet while in filter mode indicates irreversible wear of the selector valve's internal spider gasket. This rubber gasket separates the internal ports in the valve head; when it deforms or gets pinched, it allows pressurized water to flow unintentionally into the waste manifold during daily operation.
In most cases, it is enough to replace the glued gasket or the internal deflector assembly. However, if the outer body has cracks from freezing or chemical wear, it is more cost-effective to replace the head with an original replacement part such as Hayward's 6-way 1½" selector valve (SP0710X62E), which restores flow distribution without loss of flow rate in 2026.
What is the difference between a side-mounted valve and a top-mounted valve for filtration replacement parts?
The technical difference lies in the selector valve's mounting point and access to the inside of the filter tank.
- Top-mounted or top valve: screws or bolts directly onto the top opening of the filter, saving space in smaller equipment sheds but requiring the pipes to be dismantled to replace the sand bed.
- Side-mounted or side valve: attaches to the side of the tank via two separate ports, making it easier to open the top of the filter without disturbing the plumbing.
- Hydraulic maintenance: side-mounted models offer less resistance to water flow, reducing pressure loss in the system compared with compact vertical configurations.
Always purchase the variant that matches the original pipe layout to avoid structural modifications to the PVC.
I have a compact unit, and the pressure gauge shows a fixed reading above 1.5 bar. Which component in the system is failing?
A fixed reading above 1.5 bar indicates severe clogging of the filter media, a jammed pressure gauge mechanism, or a blockage in the upper diffuser. If, after backwashing and rinsing, the needle remains still with the pump off, the pressure gauge has lost its internal calibration and must be replaced immediately to prevent false readings from masking dangerous overpressure.
If the pressure gauge works correctly when the power is off but the pressure rises rapidly when the pump is switched on, the filter bed has become compacted due to calcification. In small filters with a compact pump, such as Starpool's Star 300 Sand Filter with Pump, replacing the filter media or bleeding residual air through the lid resolves backpressure issues.
How often should seals and filtration spare parts be replaced?
O-rings and elastomeric seals should be replaced every two or three operating seasons to prevent air from entering or water from leaking. Constant exposure to chemicals and temperature changes hardens the rubber, causing it to lose elasticity and compromising the watertightness of the filtration circuit.
Laterals and manifolds have a service life of around five seasons, at which point it is recommended to inspect them when replacing the silica sand or glass filter media. Pressure gauges should be checked annually at the start of the swimming season; any abnormal fluctuation or failure to return to zero when the motor is stopped means they must be replaced immediately for operational safety.
My pool pump is drawing in air and continuously losing prime. Which spare parts should I check to fix it?
Continuous loss of prime is caused by air entering through a faulty seal in the pump's pre-filter lid or suction fittings. Carefully inspect the O-ring on the clear lid; if it is cracked, flattened, or lacks neutral silicone lubricant, the system loses its vacuum and the impeller loses prime.
Another common failure point is the lower drain plug on the pump body, whose small gasket often deteriorates after winterization. For installations with compact pumps such as Saci's Optima Pump 0.25 HP Single-Phase, replacing these elastomeric gaskets restores suction performance without needing to replace the motor assembly.