{"product_id":"electrodo-ctx-go-salt-12-70327","title":"Elétrodo CTX Go Salt 12 g\/h original – Ref. 70327","description":"\u003cstyle\u003e\n#jc-70327 {\n  max-width:1600px;\n  margin:0 auto;\n  color:#263445;\n  font-size:14px;\n  line-height:1.55;\n}\n#jc-70327 * {\n  box-sizing:border-box;\n}\n#jc-70327 .jc-row {\n  display:grid;\n  grid-template-columns:minmax(0,1fr) minmax(0,1fr);\n  gap:28px;\n  align-items:start;\n}\n#jc-70327 .jc-tables {\n  grid-template-columns:minmax(0,40fr) minmax(0,60fr);\n  gap:24px;\n}\n#jc-70327 .jc-section {\n  border-bottom:1px solid #e1e7ed;\n  padding-bottom:18px;\n  margin:0;\n}\n#jc-70327 .jc-tables {\n  padding-top:32px;\n  padding-bottom:22px;\n}\n#jc-70327 .jc-faq {\n  padding-top:22px;\n  border-bottom:0;\n}\n#jc-70327 .jc-alert {\n  background:#fff9ed;\n  border-left:4px solid #c48b28;\n  border-radius:5px;\n  padding:12px 16px;\n  margin:0 0 20px;\n}\n#jc-70327 .jc-h2 {\n  color:#163b5c;\n  font-size:19px;\n  font-weight:700;\n  line-height:1.3;\n  margin:0 0 10px;\n}\n#jc-70327 .jc-h3 {\n  color:#163b5c;\n  font-size:16px;\n  font-weight:700;\n  margin:13px 0 7px;\n}\n#jc-70327 p {\n  margin:0 0 9px;\n}\n#jc-70327 p:last-child {\n  margin-bottom:0;\n}\n#jc-70327 ul,\n#jc-70327 ol {\n  margin:0;\n  padding-left:19px;\n}\n#jc-70327 li {\n  margin-bottom:5px;\n}\n#jc-70327 .jc-supply {\n  margin-top:16px;\n  padding-top:12px;\n  border-top:1px solid #e1e7ed;\n}\n#jc-70327 .jc-scroll {\n  width:100%;\n  overflow-x:auto;\n  -webkit-overflow-scrolling:touch;\n}\n#jc-70327 table {\n  width:100%;\n  border-collapse:collapse;\n  font-size:13px;\n  line-height:1.4;\n}\n#jc-70327 th,\n#jc-70327 td {\n  padding:8px;\n  text-align:left;\n  vertical-align:middle;\n  border-bottom:1px solid #e1e7ed;\n}\n#jc-70327 th {\n  background:#eef3f8;\n  color:#173b5a;\n  font-weight:700;\n}\n#jc-70327 .jc-spec th {\n  width:52%;\n  background:transparent;\n}\n#jc-70327 .is-current td {\n  background:#eef5fb;\n  font-weight:700;\n}\n#jc-70327 a {\n  color:#135b91;\n  text-decoration:underline;\n  text-underline-offset:2px;\n}\n#jc-70327 .jc-note {\n  color:#637181;\n  font-size:12px;\n  margin-top:8px;\n}\n#jc-70327 details {\n  border-bottom:1px solid #e1e7ed;\n  padding:11px 0;\n}\n#jc-70327 summary {\n  cursor:pointer;\n  color:#163b5c;\n  font-weight:700;\n}\n#jc-70327 details p {\n  margin-top:9px;\n}\n\n@media(max-width:900px) {\n  #jc-70327 .jc-tables {\n    grid-template-columns:minmax(0,1fr);\n    gap:24px;\n  }\n}\n@media(max-width:749px) {\n  #jc-70327 .jc-row {\n    grid-template-columns:minmax(0,1fr);\n    gap:20px;\n  }\n  #jc-70327 .jc-tables {\n    padding-top:24px;\n  }\n  #jc-70327 .jc-comparison table {\n    min-width:490px;\n  }\n}\n\u003c\/style\u003e\n\u003cdiv id=\"jc-70327\"\u003e\n \u003cdiv class=\"jc-alert\"\u003e\n \u003cstrong\u003eAntes de comprar:\u003c\/strong\u003e\n verifica o modelo e a referência do teu clorador.\n O elétrodo CTX 70327 é fornecido sem copo porta-célula\n nem porca de fecho.\n \u003c\/div\u003e\n \u003csection class=\"jc-section jc-row\"\u003e\n \u003cdiv\u003e\n \u003ch2 class=\"jc-h2\"\u003eElétrodo original CTX Go Salt 12 g\/h\u003c\/h2\u003e\n \u003cp\u003eO \u003cstrong\u003eelétrodo CTX 70327\u003c\/strong\u003e é a peça de substituição original para cloradores salinos CTX Go Salt de 12 g\/h.\u003c\/p\u003e\n \u003cp\u003eTem \u003cstrong\u003e5 placas\u003c\/strong\u003e e permite recuperar a capacidade nominal de produção de cloro quando a célula original chega ao fim da sua vida útil.\u003c\/p\u003e\n \u003cp\u003ePermite substituir apenas o elétrodo, sem mudar o clorador completo, desde que os restantes componentes funcionem corretamente.\u003c\/p\u003e\n \u003cdiv class=\"jc-supply\"\u003e\n \u003ch3 class=\"jc-h3\"\u003eConteúdo da substituição\u003c\/h3\u003e\n \u003cp\u003e\u003cstrong\u003eInclui:\u003c\/strong\u003e 1 elétrodo original CTX, referência 70327.\u003c\/p\u003e\n \u003cp\u003e\u003cstrong\u003eNão inclui:\u003c\/strong\u003e copo porta-célula, porca de fecho nem clorador completo.\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n \u003ch2 class=\"jc-h2\"\u003eCaracterísticas técnicas\u003c\/h2\u003e\n \u003cdiv class=\"jc-scroll\"\u003e\n \u003ctable class=\"jc-spec\"\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n\u003cth\u003eReferência\u003c\/th\u003e\n\u003ctd\u003e70327\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eFabricante\u003c\/th\u003e\n\u003ctd\u003eCTX \/ Fluidra\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eProduto\u003c\/th\u003e\n\u003ctd\u003eElétrodo de substituição\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eProdução nominal\u003c\/th\u003e\n\u003ctd\u003e12 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eNúmero de placas\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eAplicação\u003c\/th\u003e\n\u003ctd\u003eEletrólise salina\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003cth\u003eEAN\u003c\/th\u003e\n\u003ctd\u003e8435283954559\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n \u003csection class=\"jc-section jc-row jc-tables\"\u003e\n \u003cdiv\u003e\n \u003ch2 class=\"jc-h2\"\u003eCloradores compatíveis\u003c\/h2\u003e\n \u003cp\u003eEquipamentos identificados pela Fluidra para o elétrodo 70327.\u003c\/p\u003e\n \u003cdiv class=\"jc-scroll\"\u003e\n \u003ctable\u003e\n \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eRef. do equipamento\u003c\/th\u003e\n\u003cth\u003eModelo de clorador\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n\u003ctd\u003e70277\u003c\/td\u003e\n\u003ctd\u003eCTX Go Salt 12\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e70278\u003c\/td\u003e\n\u003ctd\u003eCTX Go Salt pH 12\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003cp class=\"jc-note\"\u003eVerifica a referência exata do equipamento antes de comprar. Não consideres dois elétrodos intercambiáveis apenas por terem a mesma produção.\u003c\/p\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n \u003ch2 class=\"jc-h2\"\u003eComparação de elétrodos CTX Go Salt\u003c\/h2\u003e\n \u003cp\u003eIdentifica o elétrodo correspondente ao modelo de clorador instalado.\u003c\/p\u003e\n \u003cdiv class=\"jc-scroll jc-comparison\"\u003e\n \u003ctable\u003e\n \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModelo de clorador\u003c\/th\u003e\n\u003cth\u003eCapacidade de produção\u003c\/th\u003e\n\u003cth\u003eRef. do elétrodo\u003c\/th\u003e\n\u003cth\u003eProduto\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n\u003ctd\u003eCTX Go Salt 7\u003c\/td\u003e\n\u003ctd\u003e7 g\/h\u003c\/td\u003e\n\u003ctd\u003e70326\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pt-eu\/products\/electrodo-ctx-go-salt-7-70326\"\u003eVer elétrodo\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr class=\"is-current\"\u003e\n\u003ctd\u003eCTX Go Salt 12\u003c\/td\u003e\n\u003ctd\u003e12 g\/h\u003c\/td\u003e\n\u003ctd\u003e70327\u003c\/td\u003e\n\u003ctd\u003eModelo atual\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eCTX Go Salt 21\u003c\/td\u003e\n\u003ctd\u003e21 g\/h\u003c\/td\u003e\n\u003ctd\u003e70328\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pt-eu\/products\/electrodo-ctx-go-salt-21-70328\"\u003eVer elétrodo\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eCTX Go Salt 30\u003c\/td\u003e\n\u003ctd\u003e30 g\/h\u003c\/td\u003e\n\u003ctd\u003e70329\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pt-eu\/products\/11403-electrodo-celula-30-gh-para-cloradores-ctx-go-salt\"\u003eVer elétrodo\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eCTX Go Salt 40\u003c\/td\u003e\n\u003ctd\u003e40 g\/h\u003c\/td\u003e\n\u003ctd\u003e70330\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/pt-eu\/products\/electrodo-ctx-go-salt-40-70330\"\u003eVer elétrodo\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003cp class=\"jc-note\"\u003eOs elétrodos com capacidades diferentes não são necessariamente intercambiáveis.\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n \u003csection class=\"jc-section jc-faq\"\u003e\n \u003ch2 class=\"jc-h2\"\u003ePerguntas frequentes\u003c\/h2\u003e\n \u003cdiv class=\"jc-row\"\u003e\n \u003cdiv\u003e\n \u003cdetails\u003e\u003csummary\u003eComo saber se o elétrodo está esgotado?\u003c\/summary\u003e\n \u003cp\u003eUma redução da produção de cloro pode indicar desgaste, mas também pode dever-se a problemas de salinidade, pH, caudal, incrustações ou ligações. Convém verificar estes fatores antes de substituir a célula.\u003c\/p\u003e\n \u003c\/details\u003e\n \u003cdetails\u003e\u003csummary\u003eÉ necessário substituir o elétrodo se tiver incrustações de calcário?\u003c\/summary\u003e\n \u003cp\u003eNão necessariamente. As incrustações podem reduzir o desempenho sem que o elétrodo esteja esgotado. Antes de o substituir, verifica o seu estado e segue o procedimento de limpeza recomendado pelo fabricante. Evita raspar as placas ou utilizar produtos não autorizados.\u003c\/p\u003e\n \u003c\/details\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n \u003cdetails\u003e\u003csummary\u003eQue precauções devo tomar ao substituí-lo?\u003c\/summary\u003e\n \u003cp\u003eDesliga a alimentação elétrica e interrompe a filtração. Isola e despressuriza o circuito antes de retirar a célula. Verifica o estado das juntas, do copo e das ligações, e segue as instruções do fabricante. Confirma que não existem fugas antes de retomar o funcionamento.\u003c\/p\u003e\n \u003c\/details\u003e\n \u003cdetails\u003e\u003csummary\u003eQue fatores influenciam a vida útil do elétrodo?\u003c\/summary\u003e\n \u003cp\u003eA vida útil depende das horas de funcionamento, da qualidade da água, da salinidade, das incrustações e da manutenção. Manter os parâmetros da água dentro dos valores recomendados pelo fabricante ajuda a reduzir o desgaste prematuro.\u003c\/p\u003e\n \u003c\/details\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n\u003c\/div\u003e","brand":"AstralPool","offers":[{"title":"Default Title","offer_id":51321676988743,"sku":"70327","price":574.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0875\/1307\/1943\/files\/Electrodo-clorador-salino-CTX-Go-Salt-12g-70327-w.png?v=1794217756","url":"https:\/\/www.piscinasyproductos.com\/pt-eu\/products\/electrodo-ctx-go-salt-12-70327","provider":"Piscinas y Productos","version":"1.0","type":"link"}