{"product_id":"electrodo-ctx-go-salt-40-70330","title":"Original CTX Go Salt electrode 40 g\/h – Ref. 70330","description":"\u003cstyle\u003e\n#jc-70330 {\n  max-width:1600px;\n  margin:0 auto;\n  color:#263445;\n  font-size:14px;\n  line-height:1.55;\n}\n#jc-70330 * {\n  box-sizing:border-box;\n}\n#jc-70330 .jc-row {\n  display:grid;\n  grid-template-columns:minmax(0,1fr) minmax(0,1fr);\n  gap:28px;\n  align-items:start;\n}\n#jc-70330 .jc-tables {\n  grid-template-columns:minmax(0,40fr) minmax(0,60fr);\n  gap:24px;\n}\n#jc-70330 .jc-section {\n  border-bottom:1px solid #e1e7ed;\n  padding-bottom:18px;\n  margin:0;\n}\n#jc-70330 .jc-tables {\n  padding-top:32px;\n  padding-bottom:22px;\n}\n#jc-70330 .jc-faq {\n  padding-top:22px;\n  border-bottom:0;\n}\n#jc-70330 .jc-alert {\n  background:#fff9ed;\n  border-left:4px solid #c48b28;\n  border-radius:5px;\n  padding:12px 16px;\n  margin:0 0 20px;\n}\n#jc-70330 .jc-h2 {\n  color:#163b5c;\n  font-size:19px;\n  font-weight:700;\n  line-height:1.3;\n  margin:0 0 10px;\n}\n#jc-70330 .jc-h3 {\n  color:#163b5c;\n  font-size:16px;\n  font-weight:700;\n  margin:13px 0 7px;\n}\n#jc-70330 p {\n  margin:0 0 9px;\n}\n#jc-70330 p:last-child {\n  margin-bottom:0;\n}\n#jc-70330 ul,\n#jc-70330 ol {\n  margin:0;\n  padding-left:19px;\n}\n#jc-70330 li {\n  margin-bottom:5px;\n}\n#jc-70330 .jc-supply {\n  margin-top:16px;\n  padding-top:12px;\n  border-top:1px solid #e1e7ed;\n}\n#jc-70330 .jc-scroll {\n  width:100%;\n  overflow-x:auto;\n  -webkit-overflow-scrolling:touch;\n}\n#jc-70330 table {\n  width:100%;\n  border-collapse:collapse;\n  font-size:13px;\n  line-height:1.4;\n}\n#jc-70330 th,\n#jc-70330 td {\n  padding:8px;\n  text-align:left;\n  vertical-align:middle;\n  border-bottom:1px solid #e1e7ed;\n}\n#jc-70330 th {\n  background:#eef3f8;\n  color:#173b5a;\n  font-weight:700;\n}\n#jc-70330 .jc-spec th {\n  width:52%;\n  background:transparent;\n}\n#jc-70330 .is-current td {\n  background:#eef5fb;\n  font-weight:700;\n}\n#jc-70330 a {\n  color:#135b91;\n  text-decoration:underline;\n  text-underline-offset:2px;\n}\n#jc-70330 .jc-note {\n  color:#637181;\n  font-size:12px;\n  margin-top:8px;\n}\n#jc-70330 details {\n  border-bottom:1px solid #e1e7ed;\n  padding:11px 0;\n}\n#jc-70330 summary {\n  cursor:pointer;\n  color:#163b5c;\n  font-weight:700;\n}\n#jc-70330 details p {\n  margin-top:9px;\n}\n\n@media(max-width:900px) {\n  #jc-70330 .jc-tables {\n    grid-template-columns:minmax(0,1fr);\n    gap:24px;\n  }\n}\n@media(max-width:749px) {\n  #jc-70330 .jc-row {\n    grid-template-columns:minmax(0,1fr);\n    gap:20px;\n  }\n  #jc-70330 .jc-tables {\n    padding-top:24px;\n  }\n  #jc-70330 .jc-comparison table {\n    min-width:490px;\n  }\n}\n\u003c\/style\u003e\n\u003cdiv id=\"jc-70330\"\u003e\n \u003cdiv class=\"jc-alert\"\u003e\n \u003cstrong\u003eBefore buying:\u003c\/strong\u003e\n check your chlorinator model and part number.\n The CTX 70330 electrode is supplied without a cell housing\n or retaining nut.\n \u003c\/div\u003e\n \u003csection class=\"jc-section jc-row\"\u003e\n \u003cdiv\u003e\n \u003ch2 class=\"jc-h2\"\u003eOriginal CTX Go Salt 40 g\/h electrode\u003c\/h2\u003e\n \u003cp\u003eThe \u003cstrong\u003eCTX 70330 electrode\u003c\/strong\u003e is the original replacement part for CTX Go Salt 40 g\/h saltwater chlorinators.\u003c\/p\u003e\n \u003cp\u003eThis electrode restores the rated chlorine production capacity when the original cell has reached the end of its service life.\u003c\/p\u003e\n \u003cp\u003eReplaces only the electrode without changing the complete chlorinator, provided the other components are working properly.\u003c\/p\u003e\n \u003cdiv class=\"jc-supply\"\u003e\n \u003ch3 class=\"jc-h3\"\u003eReplacement part contents\u003c\/h3\u003e\n \u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e 1 original CTX electrode, part number 70330.\u003c\/p\u003e\n \u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e cell housing, retaining nut, or complete chlorinator.\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n \u003ch2 class=\"jc-h2\"\u003eTechnical specifications\u003c\/h2\u003e\n \u003cdiv class=\"jc-scroll\"\u003e\n \u003ctable class=\"jc-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e70330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eCTX \/ Fluidra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003ctd\u003eReplacement electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated output\u003c\/th\u003e\n\u003ctd\u003e40 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eSaltwater electrolysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEAN\u003c\/th\u003e\n\u003ctd\u003e8435283954573\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n \u003csection class=\"jc-section jc-row jc-tables\"\u003e\n \u003cdiv\u003e\n \u003ch2 class=\"jc-h2\"\u003eCompatible chlorinators\u003c\/h2\u003e\n \u003cp\u003eEquipment identified in the exploded views for replacement part 70330.\u003c\/p\u003e\n \u003cdiv class=\"jc-scroll\"\u003e\n \u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eEquipment part no.\u003c\/th\u003e\n\u003cth\u003eChlorinator model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e70302\u003c\/td\u003e\n\u003ctd\u003eCTX Go Salt 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e70308\u003c\/td\u003e\n\u003ctd\u003eCTX Go Salt pH 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e72570\u003c\/td\u003e\n\u003ctd\u003eCTX Sprint Chlore V.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \u003c\/div\u003e\n \u003cp class=\"jc-note\"\u003eCheck the exact equipment part number before buying. Do not assume that two electrodes are interchangeable just because they have the same output.\u003c\/p\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n \u003ch2 class=\"jc-h2\"\u003eComparison of CTX Go Salt electrodes\u003c\/h2\u003e\n \u003cp\u003eIdentify the electrode that corresponds to the installed chlorinator model.\u003c\/p\u003e\n \u003cdiv class=\"jc-scroll jc-comparison\"\u003e\n \u003ctable\u003e\n \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eChlorinator model\u003c\/th\u003e\n\u003cth\u003eProduction capacity\u003c\/th\u003e\n\u003cth\u003eElectrode part no.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n\u003ctd\u003eCTX Go Salt 7\u003c\/td\u003e\n\u003ctd\u003e7 g\/h\u003c\/td\u003e\n\u003ctd\u003e70326\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-eu\/products\/electrodo-ctx-go-salt-7-70326\"\u003eView electrode\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eCTX Go Salt 12\u003c\/td\u003e\n\u003ctd\u003e12 g\/h\u003c\/td\u003e\n\u003ctd\u003e70327\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-eu\/products\/electrodo-ctx-go-salt-12-70327\"\u003eView electrode\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eCTX Go Salt 21\u003c\/td\u003e\n\u003ctd\u003e21 g\/h\u003c\/td\u003e\n\u003ctd\u003e70328\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-eu\/products\/electrodo-ctx-go-salt-21-70328\"\u003eView electrode\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003eCTX Go Salt 30\u003c\/td\u003e\n\u003ctd\u003e30 g\/h\u003c\/td\u003e\n\u003ctd\u003e70329\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-eu\/products\/11403-electrodo-celula-30-gh-para-cloradores-ctx-go-salt\"\u003eView electrode\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr class=\"is-current\"\u003e\n\u003ctd\u003eCTX Go Salt 40\u003c\/td\u003e\n\u003ctd\u003e40 g\/h\u003c\/td\u003e\n\u003ctd\u003e70330\u003c\/td\u003e\n\u003ctd\u003eCurrent model\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003cp class=\"jc-note\"\u003eElectrodes with different capacities are not necessarily interchangeable.\u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n \u003csection class=\"jc-section jc-faq\"\u003e\n \u003ch2 class=\"jc-h2\"\u003eFrequently asked questions\u003c\/h2\u003e\n \u003cdiv class=\"jc-row\"\u003e\n \u003cdiv\u003e\n \u003cdetails\u003e\u003csummary\u003eHow can I tell if the electrode is worn out?\u003c\/summary\u003e\n \u003cp\u003eReduced chlorine production can indicate wear, but it can also be caused by salinity, pH, flow rate, scaling, or connection issues. These factors should be checked before replacing the cell.\u003c\/p\u003e\n \u003c\/details\u003e\n \u003cdetails\u003e\u003csummary\u003eDoes the electrode need to be replaced if it has limescale buildup?\u003c\/summary\u003e\n \u003cp\u003eNot necessarily. Scale can reduce performance without the electrode being worn out. Before replacing it, check its condition and follow the cleaning procedure recommended by the manufacturer. Avoid scraping the plates or using unauthorized products.\u003c\/p\u003e\n \u003c\/details\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n \u003cdetails\u003e\u003csummary\u003eWhat precautions should I take when replacing it?\u003c\/summary\u003e\n \u003cp\u003eDisconnect the power supply and stop filtration. Isolate and depressurize the circuit before removing the cell. Check the condition of the seals, housing, and connections, and follow the manufacturer's instructions. Make sure there are no leaks before restarting the system.\u003c\/p\u003e\n \u003c\/details\u003e\n \u003cdetails\u003e\u003csummary\u003eWhat factors affect the electrode's service life?\u003c\/summary\u003e\n \u003cp\u003eService life depends on operating hours, water quality, salinity, scaling, and maintenance. Keeping water parameters within the values recommended by the manufacturer helps reduce premature wear.\u003c\/p\u003e\n \u003c\/details\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/section\u003e\n\u003c\/div\u003e","brand":"CTX","offers":[{"title":"Default Title","offer_id":51321691734343,"sku":"70330","price":940.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0875\/1307\/1943\/files\/13344.jpg?v=1742978916","url":"https:\/\/www.piscinasyproductos.com\/en-eu\/products\/electrodo-ctx-go-salt-40-70330","provider":"Piscinas y Productos","version":"1.0","type":"link"}